Below is a list of nominal baseline measurements for a variety of X-10 transmitters measured at the transmitter. Readings were made with a pre-ELK version of the ESM1 and with a 'scope through an ACT Scope-Test2. Volages measured using the Scope-Test2 are about equal to the voltages measured using a 0.1µF capacitor and 100 ohm resistor; the Scope-Test2 does not appear to have any gain.
Transmitter Volts
CM11A 5Vpp¹
CM15A 6Vpp
30001 5Vpp Stanley HomeLink Transceiver
HCPRF 6Vpp Leviton All Housecode Transceiver
RR501 10Vpp
TM751 10Vpp
PL513/PSC04 10Vpp
TW523/PSC05 10Vpp
CP290 10Vpp
MT522 10Vpp
IR543 10Vpp
PowerLinc 10Vpp
The ACT TI103 specifications indicate its output is 6Vpp. I have not measured it.
Additional data can be found in a couple of usenet threads:
Thread 1
Thread 2
Note that all of the X-10 measurement devices currently available max out at 5Vpp or less so they give an incomplete (and inaccurate) picture.
¹ The CM11A output tends to start at about 5Vpp but taper off to 3-3.5Vpp over the 1ms burst. Changing R12 as recommended by John Galvin in Thread 2 results in a steady 5Vpp output.
Although most of it dates to 2001 or earlier, there is a wealth of data on using the powerline as a communications medium at Power Line Communication Bibliography.
The effects of other transmitters on signal strength can be seen by plugging a TW523 into the same powerstrip as a TM751. The TM751 output drops from 10Vpp to 8Vpp, a 20% decrease.
NOTE: The tests were carried out circa 2003. With the exception of a TM751 and RR501 made in 2011, I have not tested newer models so do not know if there are any changes.